External Vacuum Controller
External Vacuum Controller VZP
Small in size and lightweight. External Vacuum Controller with bundled wiring dedicated to manifold mount.
Advantages
Dedicated to manifolds with bundled wiring.
Small in size and lightweight. External Vacuum Controller with bundled wiring dedicated to manifold mount.
Wiring for supply valve and air release valve is effectively concentrated in one bundle.
The concentrated wiring contributes to time saving.
Realized energy saving by holding down the valve power consumption to 0.55W.
A rich variety of pressure sensor is offered to meet the needs of a wide range of applications.
Since the number of manifold can be increased and decreased as required, it is possible to quickly respond to any change in specifications.
Push-in fitting or female thread is selectable for vacuum port to fit a piping requirement.
Specifications
Specifications
Fluid medium | Air (JIS B 8392-1:Class1.2.1~2.4.3 compliant), Vacuum |
---|---|
Operating pressure range | 0.3~0.7MPa |
Working vacuum range | -100~0kPa |
Operating temp. range | 5~50℃ (No freezing) |
Operating humidity range | 35~85%RH (No dew condensation) |
Vibration/Impact resistance | Max. 50m/s2 / Max. 150m/s2 |
Protective structure | Equivalent to IEC IP40 |
Lubrication | Not required |
Proof pressure (Air supply circuit) | 1.05MPa |
Proof pressure (Vacuum circuit) | 0.2MPa |
* Proof pressure does not indicate the pressure by which products operate normally but the pressure by which products does not break down.
Solenoid valve specifications
Rated voltage | DC24V ±10% |
---|---|
Power consumption | 0.55W (with LED) |
Surge protection | Varistor |
Operation indicator | Suction solenoid valve current application:Red LED ON |
Operation indicator | Suction solenoid valve current application:Green LED ON |
Manual operation | Push-lock button |
Vacuum supply valve specifications
Operation type | Indirect operation by pilot valve |
---|---|
Valve type | Normally closed |
Response time (OFF→ON) | 10msec |
* The response time at supply air: 0.5MPa with rated voltage (100%).
Blow-off valve specifications
Operation type | Indirect operation by pilot valve |
---|---|
Valve type | Normally closed |
Response time (OFF→ON) | 10msec |
Response time (ON→OFF) | 15msec |
* The response time at supply air: 0.5MPa with rated voltage (100%).
Vacuum filter specifications
Element material | PVF (Polyvinyl formal) |
---|---|
Filtering accuracy* | 5μm (Trapping efficiency:95%) |
Element area | 660mm2 |
* The figure under our measuring condition.
Blow-off function
Blow-off air rate | 0~50L/min[ANR] (at supply pressure 0.5MPa) |
---|
* Blow-off air rate varies according to the vacuum port dia. and tube length on vacuum side.
Pressure sensor with LED display specifications (-DW:2 switch output with LED display)
Current consumption | Max. 40mA |
---|---|
Pressure detection method | Diffusion semiconductor pressure sensor |
Operating pressure range | -100~0kPa |
Pressure setting range | -99~0kPa |
Power supply | DC12~24V ±10% Ripple (P-P) 10% max. |
Proof pressure | 0.2MPa |
No. of pressure setting | 2 |
Operating accuracy | ±3%F.S. max. (at Ta=25℃) |
Hysteresis | Fixed (2%F.S. max.) |
Switch output | NPN open collector (30V 80mA max., Residual voltage 0.8V max.) |
Response time | About 2msec |
Indication | -99~0kPa (2-digit red LED display) |
Display frequency | About 4 times/sec |
Indication accuracy | ±3%F.S. ±2 digit max. |
Sensor resolution | 1 digit |
Operational indication | SW1:Red LED turns on when pressure is above setting, SW2:Green LED turns on when pressure is above setting |
* Allowable range of the variation of “Zero point voltage”, "Span voltage" and “Pressure setting value” caused by repeated voltage application is ±3%F.S.
Pressure sensor with LED display specifications (-DA:1 switch output & 1 analog output with LED display)
Current consumption | Max. 40mA |
---|---|
Pressure detection method | Diffusion semiconductor pressure sensor |
Operating pressure range | -100~0kPa |
Pressure setting range | -99~0kPa |
Power supply | DC12~24V ±10% Ripple (P-P) 10% max. |
Proof pressure | 0.2MPa |
No. of pressure setting | 1 |
Operating accuracy | ±3%F.S. max. (at Ta=25℃) |
Hysteresis | Variable (About 0~15%F.S.) |
Switch output | NPN open collector (30V 80mA max., Residual voltage 0.8V max.) |
Analog output/Output voltage | 1~5V |
Analog output/Zero point voltage | 1 ±0.1V |
Analog output/Span voltage | 4 ±0.1V |
Analog output/Output current | 1mA max. (Load resistance:min.5kΩ) |
Analog output/LIN/HYS | ±0.5%F.S. max. (at Ta=25℃) |
Response time | About 2msec |
Indication | -99~0kPa (2-digit red LED display) |
Display frequency | About 4 times/sec |
Indication accuracy | ±3%F.S. ±2 digit max. |
Sensor resolution | 1 digit |
Operational indication | SW1:Red LED turns on when pressure is above setting |
* Allowable range of the variation of “Zero point voltage”, "Span voltage" and “Pressure setting value” caused by repeated voltage application is ±3%F.S.
Pressure sensor without LED display specifications (-S:1 switch output)
Rated voltage | DC10.8~30V (Ripple voltage included) |
---|---|
Current consumption | 20mA max. |
Pressure detection method | Diffusion semiconductor pressure sensor |
Proof pressure | 0.2MPa |
Operating pressure range | -100~0kPa |
Operating temp. range | 0~60℃ (No freezing) |
Operating humidity range | 35~85%RH (No dew condensation) |
Protective structure | Equivalent to IEC IP40 |
Switch output/Output method | NPN 2 points open collector (30V 80mA max. Residual voltage 0.8V max.) |
Switch output/No. of pressure setting | 1 |
Switch output/Pressure setting range | -99~0kPa |
Switch output/Operating accuracy | ±3%F.S. (at Ta=25℃) |
Switch output/Hysteresis | Fixed (2%F.S. max.) |
* Allowable range of the variation of “Zero point voltage”, "Span voltage" and “Pressure setting value” caused by repeated voltage application is ±3%F.S.
Pressure sensor without LED display specifications (-V1:1 analog output for negative pressure)
Rated voltage | DC10.8~30V (Ripple voltage included) |
---|---|
Current consumption | 20mA max. |
Pressure detection method | Diffusion semiconductor pressure sensor |
Proof pressure | 0.2MPa |
Operating pressure range | -100~0kPa |
Operating temp. range | 0~60℃ (No freezing) |
Operating humidity range | 35~85%RH (No dew condensation) |
Protective structure | Equivalent to IEC IP40 |
Analog output/Output voltage | 1~5V |
Analog output/Zero point voltage | 1 ±0.1V |
Analog output/Span voltage | 4 ±0.1V |
Analog output/Output current | 1mA max. (Load resistance:5Ω max.) |
Analog output/Linearity/Hysteresis | ±0.5%F.S. |
Operational indication | N.O. (Red LED turns on when pressure is above setting) |
* Allowable range of the variation of “Zero point voltage”, "Span voltage" and “Pressure setting value” caused by repeated voltage application is ±3%F.S.
Pressure sensor without LED display specifications (-R1:1 analog output for compound pressure)
Rated voltage | DC10.8~30V (Ripple voltage included) |
---|---|
Current consumption | 20mA max. |
Pressure detection method | Diffusion semiconductor pressure sensor |
Proof pressure | 0.2MPa |
Operating pressure range | -100~300kPa |
Operating temp. range | 0~60℃ (No freezing) |
Operating humidity range | 35~85%RH (No dew condensation) |
Protective structure | Equivalent to IEC IP40 |
Analog output/Output voltage | 1~5V |
Analog output/Zero point voltage | 1 ±0.1V |
Analog output/Span voltage | 4 ±0.1V |
Analog output/Output current | 1mA max. (Load resistance:5Ω max.) |
Analog output/Linearity/Hysteresis | ±0.5%F.S. |
Operational indication | N.O. (Red LED turns on when pressure is above setting) |
* Allowable range of the variation of “Zero point voltage”, "Span voltage" and “Pressure setting value” caused by repeated voltage application is ±3%F.S.
Port size
Vacuum port tube dia.
mm size(mm) | φ4, φ6 |
---|---|
Metric thread | M5x0.8 |
Air supply port tube dia.
mm size(mm) | φ4, φ6, φ8 |
---|
Vacuum supply port tube dia.
mm size(mm) | φ6, φ8, φ10 |
---|
Ordering Information
Manifold-base alone type
Mounting valve unit
Manifold installation top-mounting unit alone
Detailed Safety Instructions
Warning
1.All screws must be tightened to the correct torque referring to the instructions. The tightening torque of the solenoid valve is given in "How to install and uninstall Mounting Unit". Failure to tighten to the correct torque may result in air leaks, product detachment and damage to parts of the product.
Caution
1.When mounting the each unit on the manifold base, remove and clean any deposits on the seal area and secure it with screws. Read the "Safety Rules for Use" in the instructions carefully before use.
2.When wiring Sub-D connector and Flat Cable connector, refer to the electric circuit diagram in the instructions.
3.The vacuum performance may deteriorate or problems may occur depending on the operating conditions, be sure to understand the "Safety Rules for Use".
Frequently Asked Questions for External Vacuum Controller Series
VUS011-NW and FVXS-DW-1 are not the type of the product itself, but the type of "sensor" installed in the product. The official model code of the product is laser marked (or labeled) on the body. FVUS011-** is the sensor for Vacuum Generator VK, and FVXS-** is the sensor for Vacuum Generator VX (External Vacuum Controller VXP / VXPT).
The type of our vacuum generator complex type (External Vacuum Controller) starts with "V". (VG ..., VQ ... etc.)
The sensor model code may start with FV ... and may be written as [PRESSURE SWITCH].
The sensor model code is described only in the specifications with a sensor.
Both types indicate the valve position when the valve is unactuated. (normal position).
Normally closed type (N. C.)
Normal position is closed, covering a valve . When the valve is actuated, or electricity flows, the valve opens.
Normally open type (N. O.)
Normal position is open, uncovering a valve. When the valve is actuated, or electricity flows, the valve closes.
With the valve unactuated, the entrance leads to the exit.
There are two ways of measuring pressure, absolute pressure and gauge pressure.
Absolute pressure
Absolute pressure is zero-referenced against a perfect vacuum.
It is commonly used to measure flow rate.
When indicated, "abs" is inserted following the unit, for example 10 kPa abs.
Gauge pressure
Gauge pressure is zero-referenced against ambient air pressure.
It indicate how much pressure per 1cm2 is against the ambient air pressure. It is commonly used for indication of manometer. When the pressure is over the ambient air pressure, it is called "positive pressure" and when it is under the ambient air pressure, it is called "negative pressure."
Inquiries about this product
It is also possible to suggest products suitable for various conditions such as applications and functions. Please feel free to contact us or visit the nearest sales office.
The following are frequently asked questions. Please check before making inquiries.