Search result:{{ $data.dynamicItemsLength }}item(s)

Search result:10item(s)

News

Vacuum Generator, Multitasking / Manifold

Vacuum generator, air supply/blow-off solenoid valve and vacuum switch modules can be combined depending on vacuum system

Fluid media
Air (JIS B 8392-1:Class1.2.1~2.4.3 compliant)
Operating pressure range
0.25~0.7MPa
Operating temperature range
5~50℃(No freezing)
Operating humidity range
35~85%RH(No condensation)
Vibration/Impact resistance
Max. 50m/s2 / Max.150m/s2
Protective structure
Equivalent to IP40
Lubrication
Not required
Pressure resistance(Air supply circuit)
1.05MPa
Pressure resistance(Vacuum circuit)
0.2MPa

Vacuum Generator, Multitasking / Manifold

We offer a wide variety of vacuum modules by modularized unit combination such as ejector, switch, blow-off, vacuum retention, etc.

Fluid media
Air(JIS B 8392-1:Class1.2.1~2.4.3 compliant)
Operating pressure range
0.25~0.7MPa
Operating temperature range
5~50℃(No freezing)
Operating humidity range
35~85%RH(No condensation)
Vibration/Impact resistance
Max. 50m/s2 / Max. 150m/s2
Protective structure
Equivalent to IP40
Lubrication
Not required
Pressure resistance(Air supply circuit)
1.05MPa
Pressure resistance(Vacuum circuit)
0.2MPa

Vacuum Generator, Multitasking / Manifold

By newly adding pressure adjusting function to blow-off flow adjusting function, it enables to prevent works from being-blown away.

Fluid media
Air(JIS B 8392-1:Class1.2.1~ 2.4.3 compliant)
Operating pressure range
0.3~0.7MPa
Operating temperature range
5~50℃(No freezing)
Operating humidity range
35~85%RH(No condensation)
Vibration/Impact resistance
Max. 50m/s2 / Max. 150m/s2
Protective structure
Equivalent to IP40
Lubrication
Not required
Pressure resistance(Air supply circuit)
1.05MPa
Pressure resistance(Vacuum circuit)
0.2MPa

Options

  • No copper-based metallic material is used in flow paths
  • HNBR or FKM is used for the seal rubber material. *Some products are only compatible in the flow path.

Vacuum Generator, Multitasking / Manifold

The response characteristics of supply valve is maximized to realize a high-cycle vacuum system.

Fluid media
Air(JIS B 8392-1:Class1.2.1~ 2.4.3 compliant)
Operating pressure range
0.3~0.7MPa
Operating temperature range
5~50℃(No freezing)
Operating humidity range
35~85%RH(No condensation)
Vibration/Impact resistance
Max. 50m/s2 / Max. 150m/s2
Protective structure
Equivalent to IP40
Lubrication
Not required
Pressure resistance(Air supply circuit)
1.05MPa
Pressure resistance(Vacuum circuit)
0.2MPa

Options

  • No copper-based metallic material is used in flow paths
  • HNBR or FKM is used for the seal rubber material. *Some products are only compatible in the flow path.

Vacuum Generator, Multitasking / Manifold

31.5mm wide vacuum unit is designed to optimize the control of high vacuum flows

Fluid media
Air(JIS B 8392-1:Class1.2.1~ 2.4.3 compliant)
Operating pressure range
0.3~0.7MPa
Operating temperature range
5~50℃(No freezing)
Operating humidity range
35~85%RH(No condensation)
Vibration/Impact resistance
Max. 50m/s2 / Max. 150m/s2
Protective structure
Equivalent to IP40
Lubrication
Not required
Pressure resistance(Air supply circuit)
1.05MPa
Pressure resistance(Vacuum circuit)
0.2MPa

Options

  • No copper-based metallic material is used in flow paths
  • HNBR or FKM is used for the seal rubber material. *Some products are only compatible in the flow path.

Vacuum Generator, Multitasking / Manifold

Small size and lightweight Vacuum Generator whose wiring for supply valve and air release valve is efficiently concentrated in one bundle.

Fluid media
Air(JIS B 8392-1:Class1.2.1~ 2.4.3 compliant)
Operating pressure range
0.3~0.7MPa
Operating temperature range
5~50℃(No freezing)
Operating humidity range
35~85%RH(No condensation)
Vibration/Impact resistance
Max. 50m/s2 / Max. 150m/s2
Protective structure
Equivalent to IP40
Lubrication
Not required
Pressure resistance(Air supply circuit)
1.05MPa
Pressure resistance(Vacuum circuit)
0.2MPa

Vacuum Generator, Multitasking / Manifold

The space-saving vacuum generator equipped with direct-operated solenoid valves is best suitable for high-speed and stable response

Fluid media
Air(JIS B 8392-1:Class1.2.1 ~ 2.4.3 compliant)
Operating pressure range
0~0.55MPa
Operating temperature range
5~50℃(No freezing)
Operating humidity range
35~85%RH(No condensation)
Vibration/Impact resistance
Max. 50m/s2 / Max. 150m/s2
Protective structure
Equivalent to IP40
Lubrication
Not required
Pressure resistance(Air supply circuit)
0.85MPa
Pressure resistance(Vacuum circuit)
0.2MPa

Vacuum Generator, Multitasking / Manifold

By newly adding pressure adjusting function to blow-off flow adjusting function, it enables to prevent works from being-blown away.

Fluid media
Air(JIS B 8392-1:Class1.2.1~ 2.4.3 compliant)
Operating pressure range
0.3~0.7MPa
Operating temperature range
5~50℃(No freezing)
Operating humidity range
35~85%RH(No condensation)
Vibration/Impact resistance
Max. 50m/s2 / Max. 150m/s2
Protective structure
Equivalent to IP40
Lubrication
Not required
Pressure resistance(Air supply circuit)
1.05MPa
Pressure resistance(Vacuum circuit)
0.2MPa
  • No copper-based metallic material is used in flow paths
  • HNBR or FKM is used for the seal rubber material. *Some products are only compatible in the flow path.

Vacuum Generator, Multitasking / Manifold

The response characteristics of supply valve is maximized to realize a high-cycle vacuum system.

Fluid media
Air(JIS B 8392-1:Class1.2.1~ 2.4.3 compliant)
Operating pressure range
0.3~0.7MPa
Operating temperature range
5~50℃(No freezing)
Operating humidity range
35~85%RH(No condensation)
Vibration/Impact resistance
Max. 50m/s2 / Max. 150m/s2
Protective structure
Equivalent to IP40
Lubrication
Not required
Pressure resistance(Air supply circuit)
1.05MPa
Pressure resistance(Vacuum circuit)
0.2MPa
  • No copper-based metallic material is used in flow paths
  • HNBR or FKM is used for the seal rubber material. *Some products are only compatible in the flow path.

Vacuum Generator, Multitasking / Manifold

31.5mm wide vacuum unit is designed to optimize the control of high vacuum flows

Fluid media
Air(JIS B 8392-1:Class1.2.1~ 2.4.3 compliant)
Operating pressure range
0.3~0.7MPa
Operating temperature range
5~50℃(No freezing)
Operating humidity range
35~85%RH(No condensation)
Vibration/Impact resistance
Max. 50m/s2 / Max. 150m/s2
Protective structure
Equivalent to IP40
Lubrication
Not required
Pressure resistance(Air supply circuit)
1.05MPa
Pressure resistance(Vacuum circuit)
0.2MPa
  • No copper-based metallic material is used in flow paths