Vacuum Pad
Air Pincette
The Air Pincette, incorporating a Vacuum Pad and Vacuum Generator in the pen-shaped body, serves well in the assembly operation of small parts.
Advantages
The Air Pincette, incorporating a Vacuum Pad and Vacuum Generator in the pen-shaped body, serves well in the assembly operation of small parts.
Air Pincette incorporating a vacuum pad and vacuum generator in the pen-shaped body.
Best suitable for assembling small components.
Two types of characteristics are prepared.
Low cost VTA type (no valve incorporated) and VTB with built-in valve model which features low noise and energy saving by flowing air only during service are available.
2 types of holder types are available.
Depending on applications, two types are available:straight type and conventional curved type.
Antistatic type suitable for use on the manufacturing or assembly line that requires dissipation of static electricity and prevention of electrification is prepared.
Specifications
VTA type
Fluid medium | Air |
---|---|
Operating pressure range | 0.15~0.7MPa |
Rated supply pressure | 0.5MPa |
Nozzle bore | φ0.5mm |
Final vacuum | -85kPa |
Suction flow | 2L/min[ANR] |
Operating temp. range | 0~60℃ (No freezing) |
Air supply port | φ4mm |
VTB type
Fluid medium | Air |
---|---|
Operating pressure range | 0.15~0.7MPa |
Rated supply pressure | 0.5MPa |
Nozzle bore | φ0.4mm |
Final vacuum | -80kPa |
Suction flow | 2L/min[ANR] |
Operating temp. range | 0~60℃ (No freezing) |
Air supply port | φ4mm |
Volume resistance of Anti-static type(*)
Conductive ABS | 1x104Ω·cm |
---|---|
Conductive PA | 1x103Ω·cm |
Conductive POM | 1x102Ω·cm |
Conductive PBT | 1x103Ω·cm |
Anti-static coiling tube | 1.4x103Ω·cm |
* Volume resistance value is a representative value from a material manufacturer and is not a guaranteed value.
Port size
Pad size(mm)
φ1, φ2, φ4, φ6, φ8 |
---|
Construction
Ordering Information
Package item
Air Pincette unit
Air Pincette body alone
Option & Maintenance items
Vacuum Generator VUFilter element
Filter element for maintenance of Vacuum Generator VU and Air Pincette VTA.
Air PincetteFilter element(For VTB)
Filter element for maintenance of Air Pincette VTB.
Vacuum Filter VFUBody fixing holder
Fixing holder for maintenance of Vacuum Filter VFU and Positive/Negative Pressure Filter.
Detailed Safety Instructions
Caution
1.Do not use a machine to operate a push button for a built-in valve type. It may cause damage to the push button.
2.The filter element can be replaced by removing the ejector (without valve type: VTA) or pad holder (with built-in valve type: VTB), be sure to perform maintenance and inspection periodically. Clogging of the element may result in poor performance.
3.Note that the silencer element with built-in valve type cannot be replaced.
4.Use a coiling tube for the Air Pincette (Vacuum Pen) to minimize the load on the tube fitting.
Frequently Asked Questions for Vacuum Pad Series
The highest operative temperature limit depends on the pad material. For Urethane rubber's highest operative limit is 60℃, nitrile rubber's 110℃, and fluorine rubber's 230℃. (For the other rubber materials' highest limits, please refer to our catalogue.)
The above highest operative temperature limit is for only instant use. When the product is used under the highest operative temperature limit for a certain length of time, careful attentions are necessary.
Request of spring force change will be treated as a special order request in PISCO. Please contact your nearest sales office.
*) Please note that we cannot always meet a request of changing the spring force.
Yes, they are.
For the standard holder types such as VPC and VPD, the key way machined on the shaft gets fit with the rotation-lock thread so that it prevents the shaft rotation.
For small sized pad holders such as VPMC and VPMD, shaft itself is hexagonally machined which prevents rotation.
It is possible to minimize suction force decline of a vacuum pad by installing a fall prevention valve on multiple vacuum pads even when there are un-sucking pads.
The fall prevention valve, however, does not completely shut down the air circuit and it sucks a little amount of air. Depending on the number of un-sucking pads, required vacuum for the air circuit may not be achieved.
Besides, in case of sucking one work peace by multiple Vacuum Pads, even when the fall prevention valve can reduce vacuum decline, there is still a possibility that the work peace loose the balance so that the sucking Vacuum Pads may be released.
Please refer to the following "pad inner diameter" of the pad rubber to be attached.
Pad size | Pad inner diameter |
---|---|
φ1mm |
φ0.5mm |
φ2mm |
φ0.6mm |
φ3mm |
φ0.8mm |
φ4mm |
φ1.2mm |
No pad rubber (pad holder only) |
φ1.6mm |
*) Adsorbable up to this pad diameter
The inner diameter of the pad holder itself of the Air Pincette is φ1.6 mm, but since the pad diameter φ1 to 4 mm mentioned above has a smaller pad inner diameter than that, it is possible to adsorb workpieces of φ1.6 mm or less as shown in the above figure.
The pad inner diameter of the pad size φ6, 8 mm is larger than the pad inner diameter of the holder, so it is suitable for φ1.6 mm or more.
It is a dimensional calculation to the last, and may differ depending on the workpiece to be adsorbed. Ultimately, we ask you to judge the actual machine.
There are two ways of measuring pressure, absolute pressure and gauge pressure.
Absolute pressure
Absolute pressure is zero-referenced against a perfect vacuum.
It is commonly used to measure flow rate.
When indicated, "abs" is inserted following the unit, for example 10 kPa abs.
Gauge pressure
Gauge pressure is zero-referenced against ambient air pressure.
It indicate how much pressure per 1cm2 is against the ambient air pressure. It is commonly used for indication of manometer. When the pressure is over the ambient air pressure, it is called "positive pressure" and when it is under the ambient air pressure, it is called "negative pressure."
Inquiries about this product
It is also possible to suggest products suitable for various conditions such as applications and functions. Please feel free to contact us or visit the nearest sales office.
The following are frequently asked questions. Please check before making inquiries.