Pressure Sensor & Switch
Small Pressure Sensor 11
Small sized sensor of 24.5mm length x 10mm width
-
No copper-based metallic material is used in flow paths
-
HNBR or FKM is used for the seal rubber material. *Some products are only compatible in the flow path.
Advantages
Compact size Pressure Sensor
Small sized sensor of 24.5mm length x 10mm width
Use of an analog output type and display (SED-31 series) can make a separate display system.
Three types of pressure introduction configuration is prepared.
Stem, Male thread, and Union type are available.
3 types of pressure range and 6 types of output specification
3 pressure ranges; positive pressure range, negative pressure range, and compound pressure range and 2 output specifications; switch output and analog output making 6 different types of output specifications
Copper alloy free material and against low ozone concentration on the air flow path.
Metal parts material is non-copper metals. HNBR for seal rubber material.
Specifications
General spec.
Fluid medium | Air, non-corrosive/non-flammable gas |
---|---|
Pressure detection | Diffused metaloxide semiconductive pressure transduce, Gauge pressure |
Power supply | 10.8~30VDC (Including Ripple) |
Current consumption | 20mA or less (No-load at 24VDC) |
Storage temp. range | -20~70°C (Atmospheric pressure, Humidity:60% RH or less) |
Operating temperature range | 0~60°C (No freezing) |
Operating humidity range | 35~85% RH (No dew condensation) |
Protective structure | IEC standard IP40 equiv. |
Negative pressure type specifications
Operating pressure range | -100~0kPa |
---|---|
Proof pressure | 200kPa |
Compound pressure type specifications
Operating pressure range | -100 ~ 300kPa |
---|---|
Proof pressure | 1MPa |
Positive pressure type specifications
Operating pressure range | 0~1.0MPa |
---|---|
Proof pressure | 1.5MPa |
Switch output type Switch specifications
No. of pressure setting | 1 |
---|---|
Switch output | NPN open collector/30V 80mA or less (Residual voltage: 0.8V or less) |
Operation indicator | N.O. (Red LED turns on when pressure is above the setting.) |
Hysteresis | Fixed (2% F.S. or less) |
Operating accuracy | ±3% F.S. or less (at Ta=25℃) |
Response time | About 1msec |
Pressure setting range | Positive type:0~1.0MPa/Nagative type:-100~ 0kPa/Conpoumd type:-100~300kPa |
Analog Output Type Analog Output specifications
Output voltage | 1~5V |
---|---|
Zero-point voltage | 1 ±0.1V |
Voltage at setting pressure | 5 ±0.1V (at -100kPa) |
Output current | 1mA or less (Load resistance:5kΩ) |
Temperature characteristics | ±2%F.S.or less (at Ta=25°C) |
Linearity | ±0.5% F.S. or less (at Ta=25°C) |
Port size
Tube size
mm size (mm) | φ4, φ6 |
---|
Applicable tube fitting size
mm size (mm) | φ4, φ6 |
---|
Thread size
Metric male thread | M5x0.8 |
---|---|
Taper pipe male thread | R1/8 |
Circuit Diagram
Type & Price list
Detailed Safety Instructions
Caution
1.When adjusting the pressure of the 11 series sensor with switch output, use the small screwdriver supplied and turn gently without excessive force. Applying excessive force may cause damage to the product.
2.For the sensor head of the display unit (SED-31), use type VUS11...A, VUS12...A or SEU11...A. If the specifications of the sensor head are different, the display accuracy may not meet the specifications.
3.If other devices are connected to the same power supply as this sensor, and the SW output terminal is short-circuited with minus (-) terminal by a load operation test switch or the like while the minus (-) terminal (COM) is disconnected, the reverse current will flow to switch output circuit and the sensor will be damaged. When using this type of circuit, install a diode to prevent reverse current on the minus (-) side power supply line or on the SW output line in the direction shown in the following figure.
4.When setting the pressure and differential response, use a small screwdriver and gently turn the trimmer within its rotation range without applying excessive force. Applying excessive force may cause damage to the trimmer and to the circuit board.
5.Precautions for mounting the main unit (Thread type small pressure sensor 11 & 12 series) (1) Tighten the thread using the hexagonal-column of the main unit with an appropriate tool. (2) When tightening the threaded body, refer to the tightening torque in the table blow and the allowable torque of the tool. Failure to tighten the threaded body with proper torque may result in damage to the product or tool, loosening of the thread, or leakage.
6.Precautions for removing the main unit (Thread type small pressure sensor 11 & 12 series) (1) Remove the main unit by using the hexagonal-column of the main unit and using an appropriate tool. (2) Remove the sealant or a foreign substance on the removed mating thread. If the sealant adheres to the peripheral device, it may get into the devices and cause a malfunction.
7.Since the sensor head connector ACPG-31-CN1 is a crimp terminal, it is not necessary to remove the lead wire insulation when wiring. Wiring with the insulation removed may result in a short circuit.
Frequently Asked Questions for Pressure Sensor & Switch Series
If the pressure is not displayed on the separate display, check the following.
1)
Incorrect connection (wiring) of the connector cable
2)
Is the sensor head "analog output type"?
(Please note that the pressure indicator cannot be used with the "switch output type" sensor head.)
3)
Does the sensor type setting match the rated pressure range of the sensor head (sensor input specifications)?
Does the sensor type settings ("C-1 (compound pressure)", "C-2 (positive pressure)", "C-3 (negative pressure)") match the rated pressure range (sensor input specifications) of your sensor head ? Please check if they match. If you set a different sensor type, the correct value will not be displayed.
SED-31 sensor type setting and recommended sensor head (Reference: Excerpt from our catalog)
「C-1(compound pressure)」 VUS11-□AR
「C-2(positive pressure )」 VUS11-□A、VUS12-□A
「C-3(negative pressure)」 SEU11-□A
*)
Damaged sensor head
If a voltage higher than the power supply (V) of the sensor head and display is applied, the sensor head and display may be damaged, and as a result, the pressure may not be displayed on the pressure display. Be sure to use it within the range of the power supply (V) of the sensor head.
Inquiries about this product
It is also possible to suggest products suitable for various conditions such as applications and functions. Please feel free to contact us or visit the nearest sales office.