Vacuum Generator, Unitasking
Vacuum Generator VLS
Suction Flow Rate(Nozzle Diameter):100L/min[ANR] (φ2.0 mm), 150L/min[ANR](φ2.5 mm), 200L/min[ANR](φ2.8 mm).
Advantages
Suction Flow Rate(Nozzle Diameter):100L/min[ANR] (φ2.0 mm), 150L/min[ANR](φ2.5 mm), 200L/min[ANR](φ2.8 mm).
Square aluminum body.
Adopted a cylindrical silencer with excellent silencing effect.
Suction Flow Rate(Nozzle Diameter):100L/min[ANR] (φ2.0 mm), 150L/min[ANR](φ2.5 mm), 200L/min[ANR](φ2.8 mm).

The lineup also includes those with pressure gauges and sensors..

Specifications
Fluid medium | Air, inert gas |
---|---|
Operating pressure range | 0.15~0.7MPa |
Rated supply pressure | 0.5MPa |
Operating temp. range | 0~60℃(No freezing) |
Spec. of Digital pressure gauge
type | GPD-V-01 |
---|---|
Rated pressure range | -101~0kPa |
Pressure display range | -101~10kPa(*1) |
Proof pressure | 300kPa |
Fluid medium | Air, non-corrosive/non-flammable gas |
Battery | CR2032 Lithium Battery |
Battery life | approx. 3 years (5 times per day) |
Low-power indicator | Yes |
Battery replacement | Yes |
Turn-on interval | Display turn off after 60 sec. |
Sampling rate | 2Hz (2 times/sec.) |
Repeatability | ≦±1%F.S. ±1 digit |
LCD display | 7 segments, 3.5 digit |
Indicator accuracy | ≦±2%F.S. ±1 digit (ambient temperature at 25±3°C) |
Protective structure | IP65 (*2) |
Ambient temp. range | operation: 0~50℃, storage: -10~60℃(No dew condensation, no freezing). |
Ambient humidity range | Operation / Storage:35~85%RH (No dew condensation). |
Vibration proof | Total amplitude 1.5mm or 100m/s2, 10Hz~55Hz~10Hz for 1 minute, 2 hours in each direction of X, Y and Z |
Shock resistance | 100m/s2 |
Temperature characteristic | ±2%F.S. of detected pressure (at 25°C). |
Pressure sensor spec.
Type | VUS-32R |
---|---|
Rated pressure range | -100.0~100kPa |
Proof pressure | 300kPa |
Fluid medium | Air, non-corrosive/non-flammable gas |
Power Supply | 12VDC~24VDC (Ripple±10% or less) |
Current consumption | 40 mA or less (without load) |
Switch output type | NPN Open Collector Output/PNP Open Collector Output |
Switch Max. load current | 125 mA |
Switch output Max. supply voltage | 30VDC (NPN Open Collector Output)/24VDC (PNP Open Collector Output) |
Switch output residual voltage | 1.5V or less. |
Repeatability | ±0.2%F.S. ±1 digit or less |
Hysteresis One point set mode | adjustable (*) |
Hysteresis mode | adjustable (*) |
Hysteresis Wind comparator mode | adjustable (*) |
Response time | 2.5ms or less (Malfunction protection function:Selection from 25ms, 100ms, 250ms, 500ms, 1000ms, 1500ms) |
Overload protection | Equipped |
Digital display | 3 colors (red, green, orange) (display frequency:5 times/second) |
Display accuracy | ±2%F.S. ±1 digit or less (at Ta=25±3℃) |
Operation indicator | Orange 1 & 2 indicator lamps |
Analog output (voltage output) | Output voltage:1~5V±2.5%F.S. Output voltage: 1~5V±2%F.S. or less (within rated pressure range), Linearity: ±1%F.S. or less, Output impedance 1kΩ |
Environment proof Protective structure | IP40 |
Environment proof Ambient temp. range | Operation:0~50°C, Storage:-10~60°C (No dew condensation or freezing) |
Environment proof Ambient humidity range Operation/Storag | 35~85%RH (No dew condensation) |
Environment proof Voltage proof | AC1000V 1 min. (Between the lead wire and the case) |
Environment proof Insulation proof | Over 50MΩ (DC500V) (Between the lead wire and the case) |
Environment proof Vibration resistance | Total amplitude 1.5mm or 100m/s2 10Hz~150Hz~10Hz scan for 1 min., 2 hours in each direction of X, Y and Z. |
Environment proof Shock resistance | 100m/s2, 3 times each in direction of X, Y and Z |
Temperature characteristics | Max. ±2%F.S.(at Ta=25℃, at temp. range 0~ +50℃) |
Cable spec. | Oil proof cable (0.15mm2) |
Port size
Vacuum port
Thread size
Taper thread (female) | Rc1/2 |
---|
Air supply port
Thread size
Taper thread (female) | Rc1/2 |
---|
Vacuum Characteristic Graph




Construction

Type & Price list
Detailed Safety Instructions
Inquiries about this product
It is also possible to suggest products suitable for various conditions such as applications and functions. Please feel free to contact us or visit the nearest sales office.
The following are frequently asked questions. Please check before making inquiries.