External Vacuum Controller
External Vacuum Controller VJP (-S3 spec.)
Pressure adjusting function is added to conventional blow-off flow adjusting function.
It enables to prevent works from being blown away.
-
No copper-based metallic material is used in flow paths
-
HNBR or FKM is used for the seal rubber material. *Some products are only compatible in the flow path.
Advantages
Blow-off pressure control is available.
Pressure adjusting function is added to conventional blow-off flow adjusting function. It enables to prevent works from being blown away.
Realized shortening of blow-off time.
A relief mechanism (extra pressure is relieved) built into the blow-off circuit.
Supply valves are available in three different types.
Double solenoid type (vacuum retention type), which contributes energy saving, is suitable for a special application where continuous vacuum generation is required for a long time.
An LED display is adopted for the vacuum switch. Improved visibility.
Two types of vacuum switches are available, 2 switch outputs and analog output, with selection depending on the application.
For wiring, a connector wire is adopted to enhance the ease of designing the wiring layout.
Specifications
Specifications
Fluid medium | Air (JIS B 8392-1:Class1.2.1~2.4.3 compliant), Vacuum |
---|---|
Operating pressure range | 0.3~0.7MPa |
Working vacuum range | -100~0kPa |
Operating temp. range | 5~50℃ (No freezing) |
Operating humidity range | 35~85%RH (No dew condensation) |
Vibration/Impact resistance | Max. 50m/s2 / Max. 150m/s2 |
Protective structure | Equivalent to IEC IP40 |
Lubrication | Not required |
Proof pressure (Air supply circuit) | 1.05MPa |
Proof pressure (Vacuum circuit) | 0.2MPa |
* Proof pressure does not indicate the pressure by which products operate normally but the pressure by which products does not break down.
Solenoid valve specifications (DC24V)
Rated voltage | DC24V ±10% |
---|---|
Power consumption | 1.2W (with LED) |
Surge protection | Varistor |
Operation indicator | Current application:Red LED ON |
Manual operation | Push button (non-lock) |
Solenoid valve specifications (AC100V)
Rated voltage | AC100V ±10% |
---|---|
Power consumption | 1.5VA (with LED) |
Surge protection | Bridge diode |
Operation indicator | Current application:Red LED ON |
Manual operation | Push button (non-lock) |
Vacuum supply valve specifications (Normally closed)
Operation type | Indirect operation by pilot valve |
---|---|
Response time (OFF→ON) (DC24V) | 10msec [15msec] |
Response time (OFF→ON) (AC100V) | 13msec [18msec] |
Response time (ON→OFF) (DC24V) | 15msec [20msec] |
Response time (ON→OFF) (AC100V) | 18msec [23msec] |
*1. The response time at supply air: 0.5MPa with rated voltage (100%).
*2. The value in [] is for -S3 specifications.
Vacuum supply valve specifications (Normally open)
Operation type | Indirect operation by pilot valve |
---|---|
Response time (OFF→ON) (DC24V) | 15msec [20msec] |
Response time (OFF→ON) (AC100V) | 18msec [23msec] |
Response time (ON→OFF) (DC24V) | 10msec [15msec] |
Response time (ON→OFF) (AC100V) | 13msec [18msec] |
*1. The response time at supply air: 0.5MPa with rated voltage (100%).
*2. The value in [] is for -S3 specifications.
Vacuum supply valve specifications (Double solenoid(*1))
Operation type | Indirect operation by pilot valve |
---|---|
Response time (OFF→ON) (DC24V) | 8msec [13msec] |
Response time (OFF→ON) (AC100V) | 11msec [16msec] |
Response time (ON→OFF) (DC24V) | 8msec [13msec] |
Response time (ON→OFF) (AC100V) | 11msec [16msec] |
*1. Excitation time of the solenoid must be 50msec or more.
*2. The response time at supply air: 0.5MPa with rated voltage (100%).
*3. The value in [] is for -S3 specifications.
Blow-off valve specifications
Operation type | Indirect operation by pilot valve |
---|---|
Valve type | Normally closed |
Response time (OFF→ON) | DC24V:8msec [13msec], AC100V:11msec [16msec] |
Response time (ON→OFF) | DC24V:18msec [23msec], AC100V:21msec [16msec] |
*1. The response time at supply air: 0.5MPa with rated voltage (100%).
*2. The value in [] is for -S3 specifications.
Vacuum filter specifications
Element material | PVF (Polyvinyl formal) |
---|---|
Filtering accuracy* | 5μm |
Filter area | 1,130mm2 |
* The figure under our measuring condition.
Blow-off function
Vacuum air rate | 0~50L/min[ANR] |
---|---|
Blow-off pressure setting range | -25~25kPa |
* Blow-off air rate varies according to the vacuum port dia. and tube length on vacuum side.
Pressure sensor with LED display specifications (-W:2 switch output with LED display)
Power supply | DC12~24V ±10% Ripple (P-P) 10% max. |
---|---|
Current consumption | 40mA max. |
Pressure detection method | Diffusion semiconductor pressure sensor |
Operating pressure range | -100~0kPa |
Pressure setting range | -99~0kPa |
Proof pressure | 0.2MPa |
No. of pressure setting | 2 |
Operating accuracy | ±3%F.S. max. (at Ta=25℃) |
Hysteresis | Fixed (2%F.S. max.) |
Switch output | NPN open collector (30V 80mA max., Residual voltage 0.8V max.) |
Response time | About 2msec |
Indication | -99~0kPa (2-digit red LED display) |
Display frequency | About 4 times/sec |
Indication accuracy | ±3%F.S. ±2 digit max. |
Sensor resolution | 1 digit |
Operational indication | SW1:Red LED turns on when pressure is above setting, SW2:Green LED turns on when pressure is above setting |
* Allowable range of the variation of “Zero point voltage”, "Span voltage" and “Pressure setting value” caused by repeated voltage application is ±3%F.S.
Pressure sensor with LED display specifications (-A:1 switch output & 1 analog output with LED display)
Power supply | DC12~24V ±10% Ripple (P-P) 10% max. |
---|---|
Current consumption | 40mA max. |
Pressure detection method | Diffusion semiconductor pressure sensor |
Operating pressure range | -100~0kPa |
Pressure setting range | -99~0kPa |
Proof pressure | 0.2MPa |
No. of pressure setting | 1 |
Operating accuracy | ±3%F.S. max. (at Ta=25℃) |
Hysteresis | Variable (About 0~15%F.S.) |
Switch output | NPN open collector output (30V 80mA max., Residual voltage 0.8V max.) |
Analog output/Output voltage | 1~5V |
Analog output/Zero point voltage | 1±0.1V |
Analog output/Span voltage | 4±0.1V |
Analog output/Output current | 1mA max. (Load resistance:5kΩ max.) |
Analog output/LIN/HYS | ±0.5%F.S. max. (at Ta=25℃) |
Response time | About 2msec |
Indication | -99~0kPa (2-digit red LED display) |
Display frequency | About 4 times/sec |
Indication accuracy | ±3%F.S. ±2 digit max. |
Sensor resolution | 1 digit |
Operational indication | Red LED turns on when pressure is above setting |
* Allowable range of the variation of “Zero point voltage”, "Span voltage" and “Pressure setting value” caused by repeated voltage application is ±3%F.S.
Port size
Vacuum port tube dia.
mm size(mm) | φ4, φ6, φ8 |
---|
Air supply port tube dia.
Stand-alone type
mm size(mm) | φ4, φ6 |
---|
Manifold type
mm size(mm) | φ6, φ8, φ10 |
---|
Exhaust port tube dia.
Manifold type only
mm size(mm) | φ6, φ8, φ10 |
---|---|
or open to air |
Vacuum supply port tube dia.
Stand-alone type
mm size(mm) | φ4, φ6 |
---|
Manifold type
mm size(mm) | φ6, φ8, φ10 |
---|
Ordering Information
Detailed Safety Instructions
Warning
1.For the double solenoid type, the state of the switching valve is neutral when the supply of both pilot air to the switching valve for vacuum generation is stopped, or at the beginning of use after shipment. When resupplying pilot air, be sure to input a signal to the pilot valve or manually operate to position the switching valve in the required state before using it.
2.When using the double solenoid type in vibration, install it so that the vibration direction is perpendicular to the operating direction of the switching valve (main valve).
3.All screws must be tightened to the correct torque referring to the instructions. The tightening torque for the mounting of the product is given in "How to fix the product", and for the filter cover is given in "Replacement Element" of Vacuum Generator VJ. Failure to tighten to the correct torque may result in air leaks, product detachment and damage to parts of the product.
Caution
1.When replacing a supply port block, make sure not to lose the seal rubber and remove any foreign deposits in the vicinity, and securely tighten the screws with a torque of 0.27 to 0.3 Nm.
Frequently Asked Questions for External Vacuum Controller Series
VUS011-NW and FVXS-DW-1 are not the type of the product itself, but the type of "sensor" installed in the product. The official model code of the product is laser marked (or labeled) on the body. FVUS011-** is the sensor for Vacuum Generator VK, and FVXS-** is the sensor for Vacuum Generator VX (External Vacuum Controller VXP / VXPT).
The type of our vacuum generator complex type (External Vacuum Controller) starts with "V". (VG ..., VQ ... etc.)
The sensor model code may start with FV ... and may be written as [PRESSURE SWITCH].
The sensor model code is described only in the specifications with a sensor.
Both types indicate the valve position when the valve is unactuated. (normal position).
Normally closed type (N. C.)
Normal position is closed, covering a valve . When the valve is actuated, or electricity flows, the valve opens.
Normally open type (N. O.)
Normal position is open, uncovering a valve. When the valve is actuated, or electricity flows, the valve closes.
With the valve unactuated, the entrance leads to the exit.
There are two ways of measuring pressure, absolute pressure and gauge pressure.
Absolute pressure
Absolute pressure is zero-referenced against a perfect vacuum.
It is commonly used to measure flow rate.
When indicated, "abs" is inserted following the unit, for example 10 kPa abs.
Gauge pressure
Gauge pressure is zero-referenced against ambient air pressure.
It indicate how much pressure per 1cm2 is against the ambient air pressure. It is commonly used for indication of manometer. When the pressure is over the ambient air pressure, it is called "positive pressure" and when it is under the ambient air pressure, it is called "negative pressure."