Vacuum Pad
Vacuum Pad Sponge Type (-S3 spec.)
Best suitable for work with uneven surface such as an external wall material of building, small stone and seashell.
-
No copper-based metallic material is used in flow paths
-
HNBR or FKM is used for the seal rubber material. *Some products are only compatible in the flow path.
Advantages
Best suitable for work like an external wall material of building, small stone and seashell.
Best suitable for work-piece with rough and uneven surface like an external wall material of building, small stone and seashell.
Wide selection of pad sizes and holder types.
Silicone rubber with high mechanical strength, abrasion resistance and durability is available as a pad material.
With its high density, silicone rubber suppresses a distortion of a pad by compression.
Compliant to standards and criteria for food and food additives (Notification No. 370 of Japan's Ministry of Health and Welfare).
Best suitable for suction conveyance of food-related work-piece.
Stroke length of spring type holder can be selected.
Conventional long stroke holder (with cover) is integrated into VPC or VPD.
Stroke:6, 10, 15 and 20mm
Conventional long stroke holder (without cover) is renewed as VPOC or VPOD.
Stroke:20, 30, 40 and 50mm
The pad holder requiring for applications of "No copper alloy" and "Low-level ozone resistance" is available.
-S3 spec.:Non copper alloy is used for metal parts and HNBR or FKM is used for seal materials.
Specifications
Pad material
Material | Chloroprene rubber, Silicone rubber |
---|
Holder type
Fixed type, Top port | VPA(Standard) |
---|---|
Fixed type, Side port | VPMB(Mini)/VPB(Standard) |
Spring type, Top port | VPC(Standard) |
Spring type, Side port | VPMD(Mini)/VPD(Standard) |
Spring type, Direct mount | VPF |
Port size
Pad size(mm)
φ10, φ15, φ20, φ25, φ30, φ35, φ50, φ70, φ100 |
---|
Port tube dia.
Push-in fitting (mm) | φ4, φ6 |
---|---|
Barb fitting (tube O.D. x I.D. (mm) | φ3×φ2, φ4×φ2.5, φ6×φ4 |
* Available port size differs depending on the pad size.
Port thread size
Metric female thread | M5×0.8, M6×1 |
---|---|
Parallel pipe female thread | G1/8 |
Male thread | M14×1 |
Theoretical Suction Force Graph
Ordering Information
Model designation (example)
Detailed Safety Instructions
Warning
1.When replacing pads with a diameter of ø10 to ø30 mm, tighten the pads by hand securely until they butt against the end face. Also, when installing the pad frame, tighten it with a torque of 0.45 to 0.55 Nm using an appropriate tool, and make sure there is no loosening.
Frequently Asked Questions for Vacuum Pad Series
The highest operative temperature limit depends on the pad material. For Urethane rubber's highest operative limit is 60℃, nitrile rubber's 110℃, and fluorine rubber's 230℃. (For the other rubber materials' highest limits, please refer to our catalogue.)
The above highest operative temperature limit is for only instant use. When the product is used under the highest operative temperature limit for a certain length of time, careful attentions are necessary.
Request of spring force change will be treated as a special order request in PISCO. Please contact your nearest sales office.
*) Please note that we cannot always meet a request of changing the spring force.
Yes, they are.
For the standard holder types such as VPC and VPD, the key way machined on the shaft gets fit with the rotation-lock thread so that it prevents the shaft rotation.
For small sized pad holders such as VPMC and VPMD, shaft itself is hexagonally machined which prevents rotation.
It is possible to minimize suction force decline of a vacuum pad by installing a fall prevention valve on multiple vacuum pads even when there are un-sucking pads.
The fall prevention valve, however, does not completely shut down the air circuit and it sucks a little amount of air. Depending on the number of un-sucking pads, required vacuum for the air circuit may not be achieved.
Besides, in case of sucking one work peace by multiple Vacuum Pads, even when the fall prevention valve can reduce vacuum decline, there is still a possibility that the work peace loose the balance so that the sucking Vacuum Pads may be released.
Please refer to the following "pad inner diameter" of the pad rubber to be attached.
Pad size | Pad inner diameter |
---|---|
φ1mm |
φ0.5mm |
φ2mm |
φ0.6mm |
φ3mm |
φ0.8mm |
φ4mm |
φ1.2mm |
No pad rubber (pad holder only) |
φ1.6mm |
*) Adsorbable up to this pad diameter
The inner diameter of the pad holder itself of the Air Pincette is φ1.6 mm, but since the pad diameter φ1 to 4 mm mentioned above has a smaller pad inner diameter than that, it is possible to adsorb workpieces of φ1.6 mm or less as shown in the above figure.
The pad inner diameter of the pad size φ6, 8 mm is larger than the pad inner diameter of the holder, so it is suitable for φ1.6 mm or more.
It is a dimensional calculation to the last, and may differ depending on the workpiece to be adsorbed. Ultimately, we ask you to judge the actual machine.
There are two ways of measuring pressure, absolute pressure and gauge pressure.
Absolute pressure
Absolute pressure is zero-referenced against a perfect vacuum.
It is commonly used to measure flow rate.
When indicated, "abs" is inserted following the unit, for example 10 kPa abs.
Gauge pressure
Gauge pressure is zero-referenced against ambient air pressure.
It indicate how much pressure per 1cm2 is against the ambient air pressure. It is commonly used for indication of manometer. When the pressure is over the ambient air pressure, it is called "positive pressure" and when it is under the ambient air pressure, it is called "negative pressure."
Inquiries about this product
It is also possible to suggest products suitable for various conditions such as applications and functions. Please feel free to contact us or visit the nearest sales office.
The following are frequently asked questions. Please check before making inquiries.