Solenoid Valve
Solenoid Valve SVA
Lightweight and small-sized, yet large capacity.
Effective sectional area of 18mm2 for 16mm width valve is secured.
Advantages
Lightweight and small-sized, yet large flow capacity.
Effective sectional area of 18mm2 for 16mm width valve is secured.
Various valve types are available.
2 selections of connector lead-out direction: (Top and Side)
Vacuum-operatable 2/3 Port Solenoid Valve
Vacuum-operatable 2 or 3-way valve which does not require external piping. (Same in function as the external pilot system)
Single and Double solenoid types are available.
For manifold type, check valve to prevent back pressure is selectable as an option.
Easy maintenance by a single-screw mechanism.
Dual Pressure Option is selectable for manifold type.
Possible to control 2 different pressures in one manifold type.
DIN-rail mounting bracket is selectable as an option.
Easy and speedy attachment and detachment on DIN rail (width: 35mm)
Manifold station is installed on a DIN rail firmly.
Specifications
Specifications ofStand-alone Unit Type Sub-base
Fluid medium | Air |
---|---|
Operating pressure range | 0.2~0.7MPa |
Proof pressure | 1.05MPa |
Operating temp. range | 5~50℃ |
Installing direction | No restriction (*1) |
No. Mountable Main Valve | 1 unit |
Wiring Method | Individual Plug-in Connector, 3 pins |
* Refer to “Warning” in “Detailed Safety Instructions”.
Specifications of Manifold Sub-D connector Manifold
Fluid medium | Air |
---|---|
Operating pressure range | 0.2~0.7MPa |
Proof pressure | 1.05MPa |
Operating temp. range | 5~50℃ |
Installing direction | No restriction (*1) |
No. Mountable Main Valve | MAX. 12 units |
Wiring Method | Sub-D Connector, No. of pins:9 pins, 25 pins (*2) |
*1. Refer to “Warning” in “Detailed Safety Instructions”.
*2. 9 pins for 2 to 4 stations and 25 pins for 5 to 12 stations.
Specifications of Manifold Flat cable type Manifold
Fluid Medium | Air |
---|---|
Operating Pressure Range | 0.2~0.7MPa |
Pressure Resistance | 1.05MPa |
Operating Temp. Range | 5~50℃ |
Installing Direction | No Restriction (*1) |
Max. No. of Mountable Main Valve unit | MAX. 19 units |
Wiring Type:Flat cable connector, No. of | |
Pins:10 pins, 26 pins, and 40 pins (*3) |
*1. Refer to “Warning” in “Detailed Safety Instructions”.
*3. 10 pins for 2 to 4 stations, 26 pins for 5 to 12 stations, and 40 pins for 13 to 19 pins
Specifications of Manifold type Individual Plug-in type Manifold
Fluid medium | Air |
---|---|
Operating pressure range | 0.2~0.7MPa |
Proof pressure | 1.05MPa |
Operating temp. range | 5~50℃ |
Installing direction | No restriction (*1) |
Max. Mountable Number of Main Valve Unit | MAX. 19 units |
Wiring Type:Individual Plug-in, No. of | |
Pins:3 pins |
* Refer to “Warning” in “Detailed Safety Instructions”.
Specifications of Pilot Valve (24VDC)
Operating system | Direct acting operation |
---|---|
Valve structure | Elastic seal, Poppet valve |
Rated Coil Voltage | 24VDC |
Tolerance of voltage range | 21.6~26.4VDC |
Power Consumption | 1.2W (with LED) |
Surge protection circuit | Diode |
Manual operation | Non-Lock Push Button |
Operating Pressure Range | 0.2~0.7MPa |
Specifications of Pilot Valve (100VAC)
Operating system | Direct acting operation |
---|---|
Valve structure | Elastic seal, Poppet valve |
Rated Coil Voltage | 100VAC |
Tolerance of voltage range | 90~110VAC |
Power Consumption | 1.5VA (with LED) |
Surge protection circuit | Bridge Diode |
Manual operation | Non-Lock Push Button |
Operating Pressure Range | 0.2~0.7MPa |
Specifications of Main Valve
Operating system | Indirectly activated Pneumatic Operation by Pilot Valve |
---|---|
Valve Stracture | Spool Valve (Elastic Seal) |
Valve Type | 2-Position 5-Port/2-Position 3-Port (3-Portx2)/3-Position 5-Port/2-Position 2-Port (Vacuum-operatable valve)/2-Position 3-Port (Vacuum-operatable valve) |
Valve Function | Single/Singlex2/Double |
Response | |
Time (*2) | 18msec/12msec (varies by Valve type) |
Max. Operation Cycle | 5Hz |
Min. Excitation Time | 50msec (Double Solenoid) |
Lubrication | Not Required |
Operating pressure range | 0.2~0.7MPa/Vacuum-operatable valve:-0.1~0.7MPa |
* Values are at air pressure of 0.5MPa(OFF→ON)。Response Time for 3-Position represents the value from neutral position.
Flow Characteristics of Stand-alone unit
Item | Effective Sectional Area(mm2) |
---|---|
1(P)→4(A).2(B) (φ10mm)(*2) | 17[0.92] (SVA21S, D, T, U, V, W)/15[0.81] (SVA21E, F, G, H)/12.5[0.67] (SVA21A, R, P) |
1(P)→4(A).2(B) (φ8mm)(*2) | 16[0.86] (SVA21S, D)/14.5[0.78] (SA21E, F, G, H)/13[0.7] (SVA21T, U, V, W)/12[0.65] (SVA21A, R, P) |
1(P)→4(A).2(B) (φ6mm)(*2) | 10.5[0.56] (SVA21S, D, E, F, G, H)/9.5[0.51] (SVA21A, R, P)/8.5[0.46] (SVA21T, U, V, W) |
4(A).2(B) (φ10mm)→5(R1).3(R2) Without Exhaust Check Valve (*1) | 18[0.97] (SVA21S, D)/17.5[0.95] (SVA21V, W)/14[0.75] (SVA21A, R, P, E, F, G, H) |
4(A).2(B) (φ8mm)→5(R1).3(R2) Without Exhaust Check Valve (*1) | 17[0.92](SVA21S, D)/14[0.76] (SVA21V, W)/13.5[0.73] (SVA21A, R, P, E, F, G, H) |
4(A).2(B) (φ6mm)→5(R1).3(R2) Without Exhaust Check Valve (*1) | 10.5[0.56] (SVA21S, D)/10[0.54] (SVA21A, R, P, E, F, G, H)/9.5[0.51] (SVA21V, W) |
*1. The value of .5(R1) and 3(R2) port are those of Open-air Exhaust.
*2. 1(B) to 2(A) piping is applied to valve type T/U/ V/W.
*3. The value in [ ] is CV.
Flow Characteristics of Manifold type
Item | Effective Sectional Area (mm2) |
---|---|
1(P)→4(A).2(B) (φ8mm)(*2) | 16[0.86] (SVA20S, D)/14.5[0.78] (SVA20E, F, G, H)/13.5[0.73] (SVA20T, U, V,W)/12[0.65] (SVA20A, R, P) |
1(P)→4(A).2(B) (φ6mm)(*2) | 10.5[0.56] (SVA20S, D, E, F, G, H)/9.5[0.51] (SVA20A, R, P)/9[0.49] (SVA20T, U, V, W) |
4(A).2(B) (φ8mm)→5(R1).3(R2) With Exhaust Check Valve (*1) | 17[0.92] (SVA20S, D)/14[0.76] (SVA20V, W)/13[0.7] (SVA20A, R, P)/12.5[0.67] (SVA20E, E, G, H) |
4(A).2(B) (φ8mm)→5(R1).3(R2) Without Exhaust Check Valve (*1) | 21[1.13] (SVA20S, D)/15.5[0.84] (SVA20V, W)/15[0.81] (SVA20A, R, P)/13.5[0.73] (SVA20E, F, G, H) |
4(A).2(B) (φ6mm)→5(R1).3(R2) With Exhaust Check Valve (*1) | 10.5[0.56] (SVA20S, D)/10[0.54] (SVA20A, R, P, E, F, G, H, V, W) |
4(A).2(B) (φ6mm)→5(R1).3(R2) Without Exhaust Check Valve (*1) | 10.5[0.56] (SVA20S, D)/10[0.54] (SVA20A, R, P, E, F, G, H)/9.5[0.51] (SVA20V, W) |
*1. The value of .5(R1) and 3(R2) port are those of Open-air Exhaust.
*2. 1(B) to 2(A) piping is applied to valve type T/U/V/W.
*3. The value in [ ] is CV.
Cylinder Speed Table
Cylinder Speed (mm/s) | Cylinder Tube bore (mm) |
---|---|
100 | 〜φ140 |
200 | ~φ125 |
300 | 〜φ100 |
400 | 〜φ80 |
500 | 〜φ63 |
600 | 〜φ63 |
700 | 〜φ50 |
800 | 〜φ40 |
*1. The cylinder average speed is referential at 0.5MPa of pressure, 30% of load factor and 1m of tube length.
*2. The cylinder speed can vary according to the configuration of piping and fittings.
*3. The data represents the value when ø8mm Push-In Fitting is used on 4(A) and 2(B) ports of SVA21S-D24 or SVA20S-D24.
Flow Characteristic Graph
Ordering Information
Single Valve type
Mounting Unit
Manifold Type
Mounting Unit
DIN Rail Mounting Bracket
Detailed Safety Instructions
Caution
1.Carefully read and understand the instructions for how to replacement and piping of cartridge fittings.
2.The cartridge fitting can be attached and detached by removing the retaining pin, but make sure that the retaining pin is securely inserted before use.
Frequently Asked Questions for Solenoid Valve Series
Both types indicate the valve position when the valve is unactuated. (normal position).
Normally closed type (N. C.)
Normal position is closed, covering a valve . When the valve is actuated, or electricity flows, the valve opens.
Normally open type (N. O.)
Normal position is open, uncovering a valve. When the valve is actuated, or electricity flows, the valve closes.
With the valve unactuated, the entrance leads to the exit.
Twin 3-way valve is the valve type used for our Solenoid valve SVR10 series and SVA20 series.
One valve unit mounting manifolds is incorporated two single solenoid valves of 2 positions with 3 ports, which equals to 2 pcs of 3-way valves. Saving space is possible by that.
Two 3-way valves built in one valve unit can be controlled separately. N.C. (Normally closed) or N. O. can be also selectable for the each valve unit.
▼Twin 3-way valve video
Control of main valve in SVA20 series is carried out by air operation with the pilot valve, thus P (supply) port of the manifold requires 0.2~0.7MPa air supply. In case of 5-valve and twin 3-way valve, the supply air pressure for this P port is output at A or B port of each mounted valve.
Compressed air and vacuum corresponding 2- and 3-ports valves uses air for P (supply) port to operate the pilot valves and vacuum or compressed air circuit to be controlled are connected to A or B port of the mounted valve. When connecting, B port should be connected to air supply side, and A port should be air exhaust side (actuator side).
Even when different types of valves are mounted at the same time, there is no need to connect external pilot air, so that no wiring and saving space are realized.
Operating pressure range is -0.1~0.7MPa,
Inquiries about this product
It is also possible to suggest products suitable for various conditions such as applications and functions. Please feel free to contact us or visit the nearest sales office.
The following are frequently asked questions. Please check before making inquiries.