External Vacuum Controller
External Vacuum Controller VXP & VXPT
The response characteristics of supply valve is maximized to realize a high-cycle vacuum system.
Options
-
No copper-based metallic material is used in flow paths
-
HNBR or FKM is used for the seal rubber material. *Some products are only compatible in the flow path.
Advantages
Realizing a high-cycle vacuum system.
The response characteristics of supply valve is maximized to realize a high-cycle vacuum system.

Three-port specification has been added to the lineup of external vacuum controller. By adopting a three-way vacuum supply main valve, vacuum release time is drastically shortened.
Since the conventional two-way valve (VXP type) operates to maintain the vacuum immediately after the main valve is shut off, only blow-off air contributes to releasing vacuum. In the newly commercialized three-port specification (VXPT type), however, the atmospheric pressure is introduced when shutting off the main valve to break vacuum using the atmospheric pressure and blow-off air.

A light weight and compact vacuum unit meeting market needs.

Two types of vacuum switch are prepared.
As for vacuum switch with good visibility LED display, 2 switch outputs type, analog output & 1 switch output type and low cost analog output type are available.

Two types of installation method are available depending on the applications.
Available in the specification for fields requiring "No copper-based metal material is used in airflow paths"and "Low-level Ozone resistance".
No copper-based metal material is used in airflow paths, and sealing rubber is designed to be resistant to low-level ozone.
Specifications
Specifications
Fluid medium | Air (JIS B 8392-1:Class1.2.1~2.4.3 compliant), Vacuum |
---|---|
Operating pressure range | 0.3~0.7MPa |
Working vacuum range | -100~0kPa |
Operating temp. range | 5~50℃ (No freezing) |
Operating humidity range | 35~85%RH (No dew condensation) |
Vibration/Impact resistance | Max. 50m/s2 / Max. 150m/s2 |
Protective structure | Equivalent to IEC IP40 |
Lubrication | Not required |
Proof pressure (Air supply circuit) | 1.05MPa |
Proof pressure (Vacuum circuit) | 0.2MPa |
* Proof pressure does not indicate the pressure by which products operate normally but the pressure by which products does not break down.
Solenoid valve specifications (DC24V)
Rated voltage | DC24V ±10% |
---|---|
Power consumption | 1.2W (with LED) |
Surge protection | Varistor |
Operation indicator | Current application:Red LED ON |
Manual operation | Push button (non-lock) |
Solenoid valve specifications (AC100V)
Rated voltage | AC100V ±10% |
---|---|
Power consumption | 1.5VA (with LED) |
Surge protection | Bridge diode |
Operation indicator | Current application:Red LED ON |
Manual operation | Push button (non-lock) |
Vacuum supply valve specifications (2 port valve, Normally closed)
Operation type | Indirect operation by pilot valve |
---|---|
Response time (Standard) (OFF→ON) | DC24V:7.5msec |
Response time (Standard) (OFF→ON) | AC100V:10.5msec |
Response time (Standard) (ON→OFF) | DC24V:8.5msec |
Response time (Standard) (ON→OFF) | AC100V:10msec |
Response time (-S3) (OFF→ON) | DC24V:7.5msec |
Response time (-S3) (OFF→ON) | AC100V:10.5msec |
Response time (-S3) (ON→OFF) | DC24V:13msec |
Response time (-S3) (ON→OFF) | AC100V:22.5msec |
* The response time at supply air: 0.5MPa with rated voltage (100%).
Vacuum supply valve specifications (3 port valve, Normally closed)
Operation type | Indirect operation by pilot valve |
---|---|
Response time (Standard) (OFF→ON) | DC24V:6msec |
Response time (Standard) (OFF→ON) | AC100V:9msec |
Response time (Standard) (ON→OFF) | DC24V:8.5msec |
Response time (Standard) (ON→OFF) | AC100V:10msec |
Blow-off valve specifications
Operation type | Direct operation |
---|---|
Valve type | Normally closed |
Response time (OFF→ON) (DC24V) | 3.5msec |
Response time (OFF→ON) (AC100V) | 8msec |
Response time (ON→OFF) (DC24V) | 3msec |
Response time (ON→OFF) (AC100V) | 14msec |
* The response time at supply air: 0.5MPa with rated voltage (100%).
Vacuum filter specifications
Element material | PVF (Polyvinyl formal) |
---|---|
Filtering accuracy* | 5μm |
Filter area | 502mm2 |
* The figure under our measuring condition.
Blow-off function
Blow-off air rate (2 port valve) | 0~11L/min[ANR] (at supply pressure 0.5MPa) |
---|---|
Blow-off air rate (3 port valve) | 0~7.5L/min[ANR] (at supply pressure 0.5MPa) |
* Blow-off air rate varies according to the vacuum port dia. and tube length on vacuum side.
Pressure sensor specifications (-DW:2 switch output with LED display)
Current consumption | 40mA max. |
---|---|
Pressure detection method | Diffusion semiconductor pressure sensor |
Operating pressure range | -100~0kPa |
Pressure setting range | -99~0kPa |
Proof pressure | 0.2MPa |
Power supply | DC12~24V ±10% Ripple (P-P) 10% max. |
No. of pressure setting | 2 |
Operating accuracy | ±3%F.S. max. (at Ta=25℃) |
Hysteresis | Fixed (2%F.S. max.) |
Switch output | NPN open collector (30V 80mA max. Residual voltage 0.8V max.) |
Response time | About 2msec |
Indication | -99~0kPa (2-digit red LED display) |
Display frequency | About 4 times/sec |
Indication accuracy | ±3%F.S. ±2 digit max. |
Sensor resolution | 1 digit |
Operational indication | SW1:Red LED turns on when pressure is above setting, SW2:Green LED turns on when pressure is above setting |
* Allowable range of the variation of “Zero point voltage”, "Span voltage" and “Pressure setting value” caused by repeated voltage application is ±3%F.S.
Pressure sensor specifications (-DA:1 switch output & 1 analog output with LED display)
Current consumption | 40mA max. |
---|---|
Pressure detection method | Diffusion semiconductor pressure sensor |
Operating pressure range | -100~0kPa |
Pressure setting range | -99~0kPa |
Proof pressure | 0.2MPa |
Power supply | DC12~24V ±10% Ripple (P-P) 10% max. |
No. of pressure setting | 1 |
Operating accuracy | ±3%F.S. max. (at Ta=25℃) |
Hysteresis | Variable (0~15%F.S.) |
Switch output | NPN open collector (30V 80mA max., Residual voltage 0.8V max.) |
Analog output/Output voltage | 1~5V |
Analog output/Zero point voltage | 1 ±0.1V |
Analog output/Span voltage | 4 ±0.1V |
Analog output/Output current | 1mA max. (Load resistance:5kΩ以上) |
Analog output/LIN/HYS | ±0.5%F.S. max. (at Ta=25℃) |
Response time | About 2msec |
Indication | -99~0kPa (2-digit red LED display) |
Display frequency | About 4 times/sec |
Indication accuracy | ±3%F.S. ±2 digit max. |
Sensor resolution | 1 digit |
Operational indication | Red LED turns on when pressure is above setting |
* Allowable range of the variation of “Zero point voltage”, "Span voltage" and “Pressure setting value” caused by repeated voltage application is ±3%F.S.
Pressure sensor specifications (-A0:1 switch output & 1 analog output with LED display)
Current consumption | 15mA max. |
---|---|
Pressure detection method | Diffusion semiconductor pressure sensor |
Operating pressure range | -100~0kPa |
Proof pressure | 0.2MPa |
Power supply | DC12~24V ±10% Ripple (P-P) 10% max. |
Analog output/Output voltage | 1~5V |
Analog output/Zero point voltage | 1 ±0.1V |
Analog output/Span voltage | 4 ±0.1V |
Analog output/Output current | 1mA max. (Load resistance:5kΩ max.) |
Analog output/LIN/HYS | ±0.5%F.S. max. (at Ta=25℃) |
* Allowable range of the variation of “Zero point voltage”, "Span voltage" and “Pressure setting value” caused by repeated voltage application is ±3%F.S.
Port size
Vacuum port tube dia.
mm size(mm) | φ3, φ4, φ6 |
---|
Air supply port tube dia.
Stand-alone type
mm size(mm) | φ3, φ4, φ6 |
---|
Manifold type
mm size(mm) | φ4, φ6, φ8, φ10 |
---|
Vacuum supply port tube dia.
Stand-alone type
mm size(mm) | φ3, φ4, φ6 |
---|
Manifold type
mm size(mm) | φ4, φ6, φ8, φ10 |
---|
Ordering Information
Stand-alone type

Manifold type

Manifold-base alone

Manifold installation top-mounting unit alone

Detailed Safety Instructions
Warning
1.All screws must be tightened to the correct torque referring to the instructions. The tightening torques, for the mounting of the product is given in "How to fix body", and for the solenoid valve is given in "How to replace Valve Filter Elements". Failure to tighten to the correct torque may result in air leaks, product detachment and damage to parts of the product.
Frequently Asked Questions for External Vacuum Controller Series
VUS011-NW and FVXS-DW-1 are not the type of the product itself, but the type of "sensor" installed in the product. The official model code of the product is laser marked (or labeled) on the body. FVUS011-** is the sensor for Vacuum Generator VK, and FVXS-** is the sensor for Vacuum Generator VX (External Vacuum Controller VXP / VXPT).
The type of our vacuum generator complex type (External Vacuum Controller) starts with "V". (VG ..., VQ ... etc.)
The sensor model code may start with FV ... and may be written as [PRESSURE SWITCH].
The sensor model code is described only in the specifications with a sensor.
Both types indicate the valve position when the valve is unactuated. (normal position).
Normally closed type (N. C.)
Normal position is closed, covering a valve . When the valve is actuated, or electricity flows, the valve opens.
Normally open type (N. O.)
Normal position is open, uncovering a valve. When the valve is actuated, or electricity flows, the valve closes.
With the valve unactuated, the entrance leads to the exit.
There are two ways of measuring pressure, absolute pressure and gauge pressure.
Absolute pressure
Absolute pressure is zero-referenced against a perfect vacuum.
It is commonly used to measure flow rate.
When indicated, "abs" is inserted following the unit, for example 10 kPa abs.
Gauge pressure
Gauge pressure is zero-referenced against ambient air pressure.
It indicate how much pressure per 1cm2 is against the ambient air pressure. It is commonly used for indication of manometer. When the pressure is over the ambient air pressure, it is called "positive pressure" and when it is under the ambient air pressure, it is called "negative pressure."
Inquiries about this product
It is also possible to suggest products suitable for various conditions such as applications and functions. Please feel free to contact us or visit the nearest sales office.
The following are frequently asked questions. Please check before making inquiries.