External Vacuum Controller

External Vacuum Controller VIP

RoHS2 Compliant

Built-in flow sensor type (Industry's first) is added to the lineup. Conventional pressure sensor mount type and no pressure sensor type are also prepared.
Recommendable to semiconductor related equipment (chip mounter and handler) and vacuum transfer equipment for miniature work piece.

Advantages

Built-in vacuum flow sensor model makes confirmation of suctioning a small work-piece possible.

Built-in flow sensor type (Industry's first) is added to the lineup. Conventional pressure sensor mount type and no pressure sensor type are also prepared. Recommendable to semiconductor related equipment (chip mounter and handler) and vacuum transfer equipment for miniature work piece.

Ultra small body, but vacuum switchover with large flow is possible.

8.5L/min[ANR] or more at vacuum supply pressure -80kPa.

Blow-off air rate adjusting method is selectable.

Not only a blow-off air rate adjusting type with a needle, but also cost effective fixed flow rate type is available. (At 0.5MPa air supply, over 9.5L/min[ANR])

Specifications

Specifications

Fluid medium Air (JIS B 8392-1:Class1.2.1~2.4.3 compliant), Vacuum
Operating pressure range 0.3~0.7MPa
Working vacuum range -90~0kPa
Operating temp. range 5~50℃ (No freezing)
Operating humidity range 35~85%RH (No dew condensation)
Protective structure Equivalent to IEC IP40
Vibration/Impact resistance Max. 50m/s2 / Max. 150m/s2
Lubrication Not required
Proof pressure (Air supply circuit) 1.05MPa
Proof pressure (Vacuum circuit) 0.2MPa

* Proof pressure does not indicate the pressure by which products operate normally but the pressure by which products does not break down.

Solenoid valve specifications

Rated voltage DC24V ±10%
Power consumption 1.2W (with LED)
Surge protection Varistor
Operation indicator Current application:Red LED ON
Manual operation Push-lock button

Vacuum supply valve specifications

Operation type Indirect operation by pilot valve
Valve type Normally closed
Vacuum supply air rate (*1, *2, *3) 10L/min[ANR] (at vacuum supply pressure -80kPa)
Response time (OFF→ON) 7msec
Response time (ON→OFF) 8.5msec

*1. The value in the table is when vacuum port size is φ4mm. The air flow rate decreases by 15% with φ3mm, and by 50% with φ1.8mm.

*2. The air flow rate decreases by 30% in case of the sensor code "-A□005" and "-A□010" with vacuum port size of ø4mm or ø3mm.

*3. Vacuum supply air flow rate varies according to the vacuum port dia. and tube length on vacuum side.

*4. The response time at supply air: 0.5MPa with rated voltage (100%).

Blow-off valve specifications

Operation type Direct operation
Valve type Normally closed
Response time(*4) (OFF→ON) 3.5msec
Response time (ON→OFF) 2.5msec

*1. The value in the table is when vacuum port size is φ4mm. The air flow rate decreases by 15% with φ3mm, and by 50% with φ1.8mm.

*2. The air flow rate decreases by 30% in case of the sensor code "-A□005" and "-A□010" with vacuum port size of ø4mm or ø3mm.

*3. The response time at supply air: 0.5MPa with rated voltage (100%).

Blow-off function

Blow-off air rate Without blow-off air rate adjustment needle:9.5L/min[ANR] or more (at supply pressure 0.5MPa)
Blow-off air rate With blow-off air rate adjustment needle:Approx. 0~9.5L/min[ANR] (at supply pressure 0.5MPa)

* Blow-off air rate varies according to the vacuum port dia. and tube length on vacuum side.

Pressure sensor without LED display specifications (-V1 (Analog output))

Rated voltage DC10.8~30V (Ripple voltage included)
Current consumption 20mA
Pressure detection method Diffusion semiconductor pressure sensor
Proof pressure 1MPa
Analog output/Pressure detection range -100~0kPa
Analog output/Output voltage 1~5V
Analog output/Zero point voltage 1 ±0.04V
Analog output/Span voltage 4 ±0.04V
Analog output/Output current 1mA max.
Analog output/Temperature characteristics ±2%F.S. max. (at Ta=25℃)
Analog output/Linearity ±0.5%F.S. max.
Analog output/Output impedance 1kΩ

* Allowable range of the variation of “Zero point voltage”, "Span voltage" and “Pressure setting value” caused by repeated voltage application is ±3%F.S.

Flow sensor specifications

Rated voltage DC24V ±10%
Current consumption 30mA max. (no-load)
Operating pressure range -90kPa~0.2MPa
Proof pressure 0.3MPa
Analog output 1~5V (non-linear characteristics, connected load impedance 50kΩ or more)
Pressure characteristics ±10%F.S. max. (at Ta=25℃)
Temperature characteristics ±0.6%F.S. max. (at Ta=25℃)
Repeat accuracy ±2%F.S. max.
Response time 5msec max. (Sensor alone)
Output impedance 1kΩ

Port size

Vacuum port tube dia.

mm size(mm) φ1.8, φ3, φ4

Air supply port tube dia.

mm size(mm) φ4, φ6, φ8

Vacuum supply port tube dia.

mm size(mm) φ4, φ6, φ8

Ordering Information

Detailed Safety Instructions

Warning

1.All screws must be tightened to the correct torque referring to the instructions. The tightening torques, for the mounting of the product is given in "How to fix Stand-alone/Manifold type", and for the solenoid valve is given in "How to replace Filter Elements". Failure to tighten to the correct torque may result in air leaks, product detachment and damage to parts of the product.

Caution

1.This product is not equipped with a vacuum filter. Be sure to use PISCO vacuum filter series together. If a vacuum filter is not used, dust and dirt can accumulate inside the product, causing poor vacuum performance, leaks and malfunctioning of the solenoid valve. (Recommended vacuum filters: VFU series, VFJ series)