Vacuum Accessories
Vacuum Filter VFU
Small union type Vacuum Filter.
Corresponding product
-
No copper-based metallic material is used in flow paths
-
HNBR or FKM is used for the seal rubber material. *Some products are only compatible in the flow path.
Advantages
Small union type Vacuum Filter.
Small union type Vacuum Filter.
Small vacuum filter is suitable for a high-cycle vacuum operation.
There are 2 selections of element size depending on dust size or exchange period of the element. (Small Union Type: VFU1)
-S3 specification is available for fields requiring "No copper-based metal material is used in airflow paths" and "Low-level Ozone resistance".
HNBR for seal rubber.
Specifications
Fluid medium | Air |
---|---|
Operating pressure range | -100~0kPa |
Filtering accuracy(*1) | 5μm (Trapping efficiency : 95%) |
Operating temp. range | 0~60℃(No freezing) |
Port size
Tube dia.
mm size(mm) | φ1.8, φ3, φ4, φ6, φ8, φ10 |
---|
Thread size
Metric female thread | M3x0.5, M5x0.8 |
---|
Characteristic Graph
Construction
Type & Price list
Option & Maintenance items
Vacuum Filter VFUFilter element
Filter element for maintenance of Vacuum Filter VFU and Positive/Negative Pressure Filter.
Vacuum Filter VFUBody fixing holder
Fixing holder for maintenance of Vacuum Filter VFU and Positive/Negative Pressure Filter.
Detailed Safety Instructions
Warning
1.Small union type and union type VFU and small plug-in type: VFJ are vacuum filters. Do not use the product in a place where it will remain under pressure. Since it is not an explosion-proof, there is a risk of injury to the human body due to damage of the product.
Caution
1.Perform regular maintenance and inspection of the filter element of the vacuum filter. Clogging of the element may result in poor performance or trouble. When replacing the element, be sure to read and understand the instructions of the replacement of element, and make sure that the internal pressure of the filter is released to atmospheric pressure before replacement to ensure safety. However, the small plug-in type VFJ element cannot be replaced by itself, it must be replaced with a new one.
2.When connecting the piping, check the instructions and the arrows for the air flow direction on the product. Reverse connection does not satisfy the filter function.
3.After removing dust and replacing the element, fix the case securely and make sure there is no vacuum leakage.